4:1 input range isolated outputs efficiency to 84% overvoltage protection input filter short circuit protected fully regulated outputs input input voltage range 5 v (4.5-6.0 vdc) 12 v (9-36 vdc) 48 v (20-72 vdc) input filter network output output power 15 watts (10 w for 5 & 3,3 v versions) output voltage see table voltage accuracy ?% max voltage trim ?% max on single output models line regulation ?% max load regulation ?% max single output models, ?% for dual & triple output models, for 75% load change ripple & noise 1% of vout max (20 mhz bandwidth) temperature 0.02%/? max coefficient short circuit continuous protection remote on/off standard on triple output models, optional on single & dual output models general switching 100 khz typical frequency efficiency see table isolation 500 v dc input to output (1000 m ? /80 pf) dimensions 2.00?x 2.00?x 0.46 weight 80 g environmental operating -25 ? to +71 ? temperature storage -55 ? to +125 ? temperature 10/15 watts wu series wide input dc-dc converters specification t he xp erts i n p ower www.xpplc.com sales@xpplc.com
www.xpplc.com sales@xpplc.com dc-dc converters wide input dc-dc converters 10-15 watts wu series mechanical details remote on/off control - on >5.5 vdc or open circuit - off <1.8 vdc shutdown idle current 10 ma input resistance (e in 0 vdc to 9 vdc) 100 k ? remote on/off common referenced to input minus output may optionally be externally trimmed (?%) with a fixed resistor or an external trimpot as shown. external output trimming pin connections pin single output dual output triple output 1 + input + input remote on/off 2 - input - input - input 3 + output + output + input 4 trim common - output 5 - output - output common 6 remote on/off remote on/off 5 vdc output 7 - - + output notes: 1. voltage accuracy on 3 vdc and triple outputs ?% max. single outputs can be trimmed ?%. 2. load regulation ?% for dual and triple outputs. 3. triple outputs require minimum of 10% load for rated performance. 4. remote on/off standard on triple output units, add suffix ??to model number for option on single and dual output units. 5. pin 6 is only fitted on single and dual output models with ??suffix. single & dual output models output voltage & current ratings wu input output output input current (1) efficiency model voltage voltage current no load full load number 3.3 vdc 3000 ma 10 ma 2470 ma 80% wu100 5.0 vdc 2000 ma 10 ma 2620 ma 76% wu101 12.0 vdc 800 ma 10 ma 2520 ma 76% wu102 4.5-6.0 vdc 15.0 vdc 667 ma 10 ma 2510 ma 80% wu103 ?.0 vdc ?000 ma 10 ma 2620 ma 76% wu104 ?2.0 vdc ?00 ma 10 ma 2520 ma 76% wu105 ?5.0 vdc ?33 ma 10 ma 2510 ma 79% wu106 9-18 vdc 3.3 vdc 3000 ma 10 ma 1030 ma 80% wu200 5.0 vdc 3000 ma 30 ma 1560 ma 80% wu201 12.0 vdc 1250 ma 30 ma 1540 ma 81% wu202 15.0 vdc 1000 ma 30 ma 1525 ma 82% wu203 ?.0 vdc ?500 ma 30 ma 1560 ma 80% wu204 9-36 vdc ?2.0 vdc ?25 ma 30 ma 1540 ma 81% wu205 ?5.0 vdc ?00 ma 30 ma 1520 ma 82% wu206 5.0/?2.0 vdc 1500/?10 ma 20 ma 1576 ma 79% WU207 5.0/?5 vdc 1500/?50 ma 20 ma 1582 ma 79% wu208 5.0/+12.0/?.0 vdc 1500/310/500 ma 20 ma 1447 ma 79% wu209 18-36 vdc 3.3 vdc 3000 ma 10 ma 500 ma 83% wu300 5.0 vdc 3000 ma 20 ma 760 ma 82% wu301 12.0 vdc 1250 ma 20 ma 750 ma 83% wu302 15.0 vdc 1000 ma 20 ma 745 ma 84% wu303 ?.0 vdc ?500 ma 20 ma 760 ma 82% wu304 20-72 vdc ?2.0 vdc ?25 ma 20 ma 750 ma 83% wu305 ?5.0 vdc ?00 ma 20 ma 745 ma 84% wu306 5.0/?2.0 vdc 1500/?10 ma 15 ma 778 ma 80% wu307 5.0/?5.0 vdc 1500/?50 ma 15 ma 781 ma 80% wu308 5.0/+12.0/?.0 vdc 1500/310/500 ma 15 ma 715 ma 80% wu309 36-72 vdc 3.3 vdc 3000 ma 10 ma 245 ma 84% wu400 triple output models dimensions in inches (mm) 1. input current is at nominal input voltage. notes rev 2.0
|